Introducing Kardia 12L: The first of its kind 12-lead portable ECG | Learn More

AliveCor Logo

Our Products

AFib Screening
Data Integration Solutions
KardiaCare Plus
KardiaComplete
Kardia 12L

New

KardiaMobile 6L
AliveCor K1000
KardiaStation
KardiaPro
Kardia ECG Devices

Our Solutions

Health Systems
Clinical Trials
Payors
Employers
OEMs
Veterans Affairs

About

Leadership
Mission
Clinical Research
Our AI
For Consumers
The Human Component Film
Newsroom
(855) 338-8800
AliveCor Logo
AliveCor Logo
  • Instagram
  • Facebook
  • Twitter
  • LinkedIn
    • (855) 338-8800
    • Mission
    • Careers
    • Research
    • Newsroom
    • FAQs
    • User Manuals
    • Compatibility
    • Shipping
    • (855) 338-8800
    • KardiaMobile Card
    • KardiaMobile 6L
    • KardiaMobile
    • KardiaCare
    • International
  • Instagram
  • Facebook
  • Twitter
  • LinkedIn
  • Privacy Policy
  • Security
  • Telehealth Informed Consent
  • Terms
  • Accessibility

©2024 AliveCor, Inc. All Rights Reserved. Patents www.alivecor.com/patents. AliveCor and Kardia are trademarks of AliveCor, Inc. in the United States and other countries. Apple is a trademark of Apple, Inc. registered in the U.S. and other countries. App Store is a service mark of Apple, Inc. Android is a trademark of Google Inc. Google Play is a trademark of Google Inc.

Contact Us

Mobile 12-lead ECG System

Introducing Kardia 12L

The easiest way to acquire a 12-lead ECG, making critical data accessible in more places, more often.

Learn how Kardia 12L can transform your practice with our free guide.

Get the Guide Contact us for pricing

For healthcare professional use only

Kardia Device
Kardia Device

Reimagining the 12-lead ECG experience.

We challenged our engineers, clinicians, and data scientists to rethink the 12-lead ECG. The resulting technology underscores our commitment to transform cardiovascular care — simplifying and expediting access to critical cardiac data.

See How

One-cable design + AI trained with one million ECGs.

The FDA-cleared Kardia 12L is an AI-powered handheld 12-lead resting ECG system. With simplified leadset technology, Kardia 12L offers outstanding clinical efficiency that expands access to 12-lead recordings in more settings than ever before.

Its unique single-cable design makes lead placement more intuitive and less error-prone, so even qualified personnel with infrequent ECG experience can acquire an accurate recording in minutes.

And with 1 million ECGs from leading U.S. medical institutions, our team developed a robust algorithm with multiple deep neural network AI models. The Kardia 12L ECG algorithm received FDA 510(k) clearance by demonstrating substantial equivalence to the state-of-the-art 12-lead ECG algorithm.

See the 35 FDA-cleared determinations it can detect.

Streamlined 3-step workflow

1. Get started with the KardiaStation app

2. Record a 12-lead ECG

3. Share ECGs for quick review

Lead placement options

Electrodes can be placed on the supine patient in either the Default or Alternate lead set locations. The KardiaStation app will guide you to select the appropriate lead placement, based on patient symptoms. Ensure Right Arm lead is placed first in order for the Leads Off function to display properly.

none

Download Quickstart Guide

Comparison to conventional 12-lead results

Standard 12-lead ECG vs. Kardia 12L ECG report

Recent data presented at Heart Rhythm Society 2024, "Diagnostic accuracy of a mobile, artificial intelligence-guided, 12-lead ECG device," showed results from a clinical study on 200 patients. See the side-by-side ECG reports from a standard 12-lead compared to one from the Kardia 12L for the same patients.

The study found that Kardia 12L enabled rapid acquisition of resting ECG information, and concluded "this approach has significant implications for rapid ECG diagnosis in clinical practice."

The poster can be accessed here.

Additional Features

High-quality ECG and analysis

none

35 FDA-cleared ECG determinations

none

Light and portable, only 0.3lbs

none

Easy to use and interpret

Kardia 12L detects a comprehensive set of 35 FDA-cleared determinations

Rhythm Determinations

Normal Sinus Rhythm
Sinus Rhythm
Atrial Fibrillation
Atrial Flutter
1st Degree AV Block
High degree AV block (including 2nd and 3rd degree AV blocks)
Sinus Arrhythmia
Marked Sinus Arrhythmia
Paced Rhythm
Marked Bradycardia (SR, Bradycardia)
Junctional Rhythm
Sinus Tachycardia (SR, Tachycardia)
Bigeminy
PVCs

Morphology Determinations

Right bundle branch block (RBBB)
Left bundle branch block (LBBB)
Other Intraventricular Block
Left Ventricle Hypertrophy (LVH)
Right Ventricle Hypertrophy (RVH)
Right Atrial Enlargement (RAE)
Left Atrial Enlargement (LAE)
Old Anterior MI
Old Inferior MI
Old Lateral MI
Acute Anterior MI
Acute Inferior MI
Acute Lateral MI
Anterior Ischemia
Inferior Ischemia
Lateral Ischemia
Early Repolarization
Prolonged QT
Paced ECG
Wolff-Parkinson-White (WPW)
Normal ECG

The provisional automated ECG analysis should not be used for clinical action if it has not been reviewed by a healthcare professional qualified to independently interpret the ECG signal. The four synthesized chest leads are not intended for diagnostic use

View the 2025 Kardia 12L Coding Guidelines here.

To learn more about Kardia 12L, download our free guide.

Contact Us

Legal

1Whyte, Seabrook, et al. "Diagnostic accuracy of a mobile, artificial intelligence-guided, 12-lead ECG device." Poster presented at: Heart Rhythm Society 2024; May 16-19, 2024; Boston MA, USA.

2The provisional automated ECG analysis should not be used for clinical action if it has not been reviewed by a healthcare professional qualified to independently interpret the ECG signal. The four synthesized chest leads are not intended for diagnostic use

Kardia 12L is intended for use by qualified healthcare professionals or trained personnel.